Simpson228 ,AC/DC Leakage Current Tester
Simpson228 ,AC/DC Leakage Current Tester,Designed to meet new IEC, ANSI, and UL guidelines
Simpson228 ,AC/DC Leakage Current Tester
Test for dangerousleakagecurrentwiththeSimpsonModel228,designed to meet thelatestUL,IEC,andANSIspecifications.The228 detects both ACandDCleakagecurrentandsimulateshumanresponse atthreedifferentlevels--reaction,let-go, andburnhazard. Each Model228comeswithtestleads withalligatorclips,manual, andbatteries.
- Detects dangerous AC&DCleakagecurrentpresentontheconductive surfacesofelectricalorelectronicequipment
- Designed to meet new IEC, ANSI, and ULguidelines
- Reaction, Let-Go and Unweighted Burn Hazardnetworkmeasurements
- Battery-powered for maximum portability
Simpson 228 Special Purpose AC/DC Milliameter Designed specificallytomeasurehazardous"LeakageCurrents"or"TouchCurrents"which mayappearwhenapersontouchestheconductive surfaceofelectricalorelectronicequipment.The228is designed inaccordancewithIEC,ANSIandULguidelines. • True RMS Readings • Reads in Measurement Indication Units (MIU) up to .005 MIU • Output AllowsMeasurementofPeakCurrentinNon-SinusoidalWaveForms • Let-Go, Reaction, and Burn Hazard Response Networks • Detects dangerous AC & DC Leakage currents • Includes Test Leads, Alligator Clips, Batteries and Manual | |
Specifications
GENERAL | Reaction ResponseNetwork | Let-Go ResponseNetwork | UnweightedBurnHazard Response Network |
Equivalent network component values: | Complies with values specified in IEC 990 (excluding fuse) |
Equivalent measuring instrument load: | 1 MΩ- 10pF | 1 MΩ- 62 pF | 1 MΩ- 1 pF |
Ranges: | 0.3, 1, 3, 10 M.I.U. | 0.3, 1, 3, 10 M.I.U. | 0-100 mA RMS |
Current accuracy: | ±2% F.S. @ 60 Hz |
Meter measurement method: | True RMS |
Meter frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) |
DC to 1 Hz | Pointer shall track within 5% of peak |
2Hz to 19Hz (Accuracy not supported) | |
20 Hz to 200 KHz | ±2% F.S. | ±2.5% of F.S. | ±2% F.S. |
200 KHz to 1 MHz | ±2% F.S. | ±2.5% F.S. | ±5% F.S. |
Output sensitivity: | Full scale meter indication equals 1V RMS (Measured with a 1 MΩ- 12 pF load) |
Output accuracy: | ±2% of reading @ 60 Hz |
Output frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) |
DC to 50Hz | ±2% of reading |
50 Hz to 100 KHz | ±2.5% of reading | ±2% /-3% of reading | ±2% of reading |
100 kHz to 1 MHz | ±5% of reading |
Voltmeter range: | 0-300 V (AC or DC) |
Voltmeter accuracy: DC to 1 Hz | Pointer shall track within 5% of peak |
2Hz to 19Hz (Accuracy not supported) | |
20 Hz to 1KHz | ±3% F.S. @ 60 Hz (Add ±1% for every additional 100Hz) |
Voltmeter frequency response: | DC to 1 KHz |
Power requirements: | Power requirements: (2) 9V (NEDA 1604A) batteries |
Physical: | 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg),ABSplastic,fusedinput |
Environmental: | 27°C ±2° C, 70% non condensingrelativehumidity.Outsidethisrangederateby10% per °C |
Maximum operating range: | 0° to 40° C |
Simpson228 ,AC/DC Leakage Current Tester
Simpson228 ,AC/DC Leakage Current Tester